User manual of EC160 elevator intelligent integrated machine Running at slow speed
149
[Y] [N]
Select [Yes] and enter:
【motor static autotuning】
Whether begin the motor autotuning?
[Y] [N]
Select [Yes] and enter, and press the up inspection button:
【motor static autotuning】
Motor autotuning…
If succeeded, then
【motor static autotuning】
Autotuning succeeded
If failed, then
【motor static autotuning】
Autotuning failed
Save the parameters after autotuning.
The static autotuning of asynchronous motor is the same as above.
After finishing autotuning, update P2_06~P2_10.
To ensure the accuracy, there will be about 4 minutes for the static
autotuning of asynchronous motor and discontinuous electromagnetic
acoustic. After the end of autotuning, the operator will prompt
autotuning succeeded or failed.
7.4 Rotating autotuning of the motor
Ensure the wire rope on the motor is removed before the rotating autotuning and the input
parameters are correct.
Function
code
Name Instruction
P0_00 Speed control mode 0-2【1】
P2_00 Motor type 0: AM 1: SM
P2_01 Rated power of the motor Depend on the name plate
P2_02
Rated frequency of the
motor
Depend on the name plate
P2_03 Rated speed of the motor Depend on the name plate
P2_04 Rated voltage of the motor Depend on the name plate