User manual of EC160 elevator intelligent integrated machine Debugging tools
41
Chapter 5 Debugging tools
5.1 Instruction
Manual controller is the specific debugging tools for system debugging and maintenance. It consists
of LCD display and keys which has following functions:
5.1.1 Main controlling interface
Following elevator state can be watched through LCD displaying:
¾ The automotive, maintenance, attendant, fire safety, overload and door open state;
¾ Inside and outside calling signal of the elevator;
¾ Floor position of the elevator;
¾ Running direction of the elevator.
5.1.2 Fault record
Inquiry the fault time, floor, input/output state.
5.1.3 Parameters setting
Set all the elevator parameters through the manual controller
¾ Speed setting;
¾ Motor parameters setting;
¾ Encoder parameters setting;
¾ Floor parameters setting;
¾ Comfortability and protective parameters setting;
¾ Time and function parameters setting
5.1.4 Password setting
The password of the loading page can be modified and the current password can be used to modify
the current password and the lower grade password.
5.1.5 System autotuning
Relative elevator autotuning:
¾ Hoistway autotuning of the elevator;
¾ Static autotuning of the motor;
¾ Rotating autotuning of the motor;
¾ Weighing autotuning.
5.1.6 Data management
¾ Data storage;