User manual of EC160 elevator intelligent integrated machine Function parameters
122
Function
code
Instruction Setting rangedefault value Remarks
T0_10 Arrival gong delay 0~5.000s0.000
Not modify
in running
Set the time from the arrival gong output to canceling the arrival gong.
Function
code
Instruction Setting rangedefault value Remarks
T0_11 Thermal protection reset delay 0~5000s600
Not modify
in running
Set the time from thermal protection switch reset to rerunning of the elevator.
Function
code
Instruction Setting rangedefault value Remarks
T0_12 Pre-opening delay 0~5.000s0.000
Not modify
in running
T0_13 Peristaltic landing overtime 0~5.000s0
Set the pre-opening delay. When satisfying pre-opening and short circuiting door lock, delay
opening. And set it to 0 to cancel the function.
Set the protection time of peristaltic landing running (coordinate with peristaltic landing speed)
and set it to 0 to cancel the function.
After T0_12 or T0_13 is set, Y5 will be forced as low speed signal output.
Function
code
Instruction Setting rangedefault value Remarks
T0_14 Speed reference delay 0~5.000s 0.500
Not modify
in running
Set the time from the brake output and receiving the feedback to the reference speed.
Function
code
Instruction Setting rangedefault value Remarks
T0_15 Braking voltage shifting delay 0~5.000s0.000
Not modify
in running