User manual of EC160 elevator intelligent integrated machine Function parameters
136
0 original definition of front/rear door output
1 output contactor control 1
2 star-delta output
3 brake contactor control 1
4 brake contactor control 2
5 fire return
6 front door opening output
7 front door closing output
8 rear door opening output
9 rear door closing output
10 pre-opening output
11 low speed signal
12 UPS control
13 elevator lock return
14 energy-saving output
15 forced closing output
16 elevator up signal
17 important fault signal
18 reserved
19 reserved
20 reserved
21~99 no definition
When using pre-opening or peristaltic landing, Y5 is forced as low
speed signal and Y6 is forced as pre-opening request.
Function
code
Instruction Setting range【default value】 Remarks
F0_75 Analog LL set voltage 0~65535【0】
Not modify
in running
F0_76 Analog FL set voltage 0~65535【0】
F0_77 Analog OL set voltage 0~65535【0】
After setting P4.23 to non-zero, F0_75, F0_76 and F0_77, obtain the load state by setting voltage
without need of load autotuning.
6.5.19 Parameters setting---calling signal
【main menu】
A system control
B fault record
C language
selection
D parameters
setting inquiry
E password setting
F system autotuning
G data management
H system
information
【parameters setting
inquiry】
P0 master drive control
P1 speed and
deceleration distance
P2 motor parameters
P3 encoder parameters
P4 running comfortability
P5 elevator protection
parameters
P6 communication setting
P7 drive information
PE factory only
【U0 calling signal】
Random calling
enabling