User manual of EC160 elevator intelligent integrated machine EC160 configuration
11
No.
Function
name
Function instruction Remarks
the hall for
calling service
control
function. The user can only record the calling command
with a card.
card
7
Single door
operator and
single control
box
Default configuration
Configure
single control
box
8
Single door
operator and
dual control
box
Use one EC-CTB and two EC-CCB, the buttons and lights
of two control boxes have the same connection. Need to
short circuit the input terminal of car top board BAK.
Configure
dual control
box
9
Dual door
operator and
single control
box
In conditions that there is only front or rear door, and the
doors both open or close simultaneously. (Select dual
control box when either front door or rear door controls
independently.)
Configure
single control
box
10
Dual door
operator and
dual control
box
(independent
front/rear door
control)
Use one EC-CTB and two EC-CCB. Front door opens in
response to front door calling or for the open button or
inside command of main control box when landing. Rear
door opens in response to rear door calling or for the open
button or inside command of sub control box when
landing. Need to set F0_09 to 0.
Configure
dual control
box
11
Remote
monitoring
Monitor the floor position, running direction and fault state
at real time in the remote monitoring center. Support 3G
network.
Configure
according to
actual plan
12
GPRS remote
alarm
After setting and connecting DM-03, elevator fault will be
informed to the monitoring center and the short message
will be sent to the maintainer.
Configure
DM-03
13
Ethernet
real-time
monitoring
Monitor the running data of the elevator at real time
(sample at the fastest 0.5ms) through PA_DP/E
Configure
PA_DP/E
14
Group control
running
As many as 8 elevators
Configure
MC-GCL