RL78/G1H CHAPTER 14 SERIAL ARRAY UNIT
R01UH0575EJ0120 Rev. 1.20 Page 354 of 920
Dec 22, 2016
14.5 Operation of 3-Wire Serial I/O (CSIp) Communication
This is a clocked communication function that uses three lines: serial clock (SCK) and serial data (SI and SO) lines.
[Data transmission/reception]
• Data length of 7 or 8 bits
• Phase control of transmit/receive data
• MSB/LSB first selectable
[Clock control]
• Master/slave selection
• Phase control of I/O clock
• Setting of transfer period by prescaler and internal counter of each channel
• Maximum transfer rate
Note
During master communication: Max. fCLK/4
During slave communication: Max. f
MCK/6
[Interrupt function]
• Transfer end interrupt/buffer empty interrupt
[Error detection flag]
• Overrun error
Note Use the clocks within a range satisfying the SCK cycle time (t
KCY) characteristics. For details, see
CHAPTER 31 ELECTRICAL SPECIFICATIONS.