Development Unit
SM 4-45 D062/D063/D065/D066
Replacement
and
Adjustment
Automatic process control starts automatically after the machine is switched
on, so after replacing the developer, you should enter the SP mode and
initialize the developer with SP2801 as soon as possible after switching the
machine on.
2. Do SP2801 (TD Sensor Initial Setting).
Open the front door.
Turn the machine on
If you open the front door, auto process control will not start. SP2801 must be
done before auto process control starts.
Push Clear Modes
Enter the SP mode.
Close the front door.
Push "System SP" on the touch-panel.
Push
to select SP2801-002.
On the soft keys, enter the lot number from the pack of developer, then push
.
Do SP2801-1.
4.7.2 DEVELOPMENT FILTER
Remove:
Development unit (
p.4-25 "Drum Removal")
Pressure release tube, only for D066 (
p.4-43 "Developer Replacement")
1. Toner hopper [A]
2. Filter bracket top [B]
3. Development filter [C]
4. Filter bracket [D]
Make sure that the rails where the development filter bracket [C] connects to the
development unit are clean and free of toner. If there is any toner in the rails, wipe