Development Unit
D062/D063/D065/D066 4-48 SM
2. Before installing a new TD sensor, clean the TD sensor port [B].
3. After replacing the TD sensor, do these SPs:
SP2801 TD Sensor Initial Setting
SP2962 Auto Process Control (only if SP3901 – Auto Process Control – is on).
4.7.5 TONER END SENSOR
Remove:
Development unit ( p.4-43 "Removal ")
1. Toner hopper [A] (
x 2)
2. Toner end sensor [B] (
x 2)
Remove the screws carefully to avoid stripping the holes.
Before installing a new toner end sensor, clean the toner end sensor port [C].
4.7.6 TONER SUPPLY MOTOR
1. Open the front door.
2. Swing the toner unit out of the machine and remove the toner bottle.
3. Bracket [A] (
x 1)