SP5802 Free Run Mode
Execute this SP to force base engine to run in
the free run mode for testing.
SP5803 Input Check
Displays the signals received from sensors and
switches. Refer to the detailed tables in "Service
Tables”.
SP5804 Output Check
Switches electrical components one by one for
testing. Refer to the detailed tables in "Service
Tables”.
SP5990 SMC Printout
Prints the SMC Report. Some SC codes (logged
SPs) are shown only in the SMC Report and do
not show on the operation panel display.
SP7801 ROM Version Display.
Displays the version number of the main
machine and connected peripherals.
SP7832
Self-Diagnostic Result
Display
Execute this SP to display a list of error codes.
No errors have occurred if nothing is displayed.
SP7801 Firmware Version
Displays the current numbers of all versions of
the firmware in the system.
SP7403 Status of Issued SC
Execute to display the following information
about the most recently issued SC: 1) Source
file name, 2) SC number, 3) Result