Main SP Tables-2-1
D146/D147/D148/D149/D150 2-146 System Maintenance Section
2.3 MAIN SP TABLES-2-1
2.3.1 SP2-005 TO 2-473 (DRUM)
2005
[Charge DC Voltage: Fixed]
DC fixed voltage when Process control is off.
001 Standard Speed: K *ENG [0 to 2000 / 650 / 10-V/step]
002 Standard Speed: C *ENG
[0 to 2000 / D146: 1300, D147:
1300, D148: 650, D149: 650, D150:
650 / 10-V/step]
003 Standard Speed: M *ENG
004 Standard Speed: Y *ENG
005 Middle Speed: K *ENG [0 to 2000 / 650 / 10-V/step]
006 Middle Speed: C *ENG
[0 to 2000 / D146: 1300, D147:
1300, D148: 650, D149: 650, D150:
650 / 10-V/step]
007 Middle Speed: M *ENG
008 Middle Speed: Y *ENG
009 Low Speed: K *ENG [0 to 2000 / 650 / 10-V/step]
010 Low Speed: C *ENG
[0 to 2000 / D146: 1300, D147:
1300, D148: 650, D149: 650, D150:
650 / 10-V/step]
011 Low Speed: M *ENG
012 Low Speed: Y *ENG
2005
[Charge DC Voltage: Correction]
Correction amount for AC center value.
013 PCU: Standard Speed *ENG
[-100 to 100 / 0 / 1-V/step]
014 PCU: Middle Speed *ENG
015 PCU: Low Speed *ENG
2005
[Charge DC Voltage: Correction]
Vc calculating coefficient of DC Electrify.
018 Correction Coefficient a: K *ENG [0.000 to 2.000 / 1.000 / 0.001/step]