Line Commands
4-15
4
silent-time
Use this command to set the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts exceeds the threshold
set by the password-thresh command. Use the no form to remove the silent time
value.
Syntax
silent-time seconds
no silent-time
seconds - The number of seconds to disable console response.
(Range:
0-65535; 0: no silent-time)
Default Setting
The default value is no silent-time.
Command Mode
Line Configuration
Example
To set the silent time to 60 seconds, enter this command:
Related Commands
password-thresh (4-14)
databits
Use this command to set the number of data bits per character that are interpreted
and generated by the console port. Use the no form to restore the default value.
Syntax
databits {7 | 8}
no databits
• 7 - Seven data bits per character.
• 8 - Eight data bits per character.
Default Setting
8 data bits per character
Command Mode
Line Configuration
Console(config-line)#silent-time 60
Console(config-line)#

Table of Contents

Other manuals for Enterasys Matrix-V V2H124-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix-V V2H124-24 and is the answer not in the manual?

Enterasys Matrix-V V2H124-24 Specifications

General IconGeneral
BrandEnterasys
ModelMatrix-V V2H124-24
CategorySwitch
LanguageEnglish

Related product manuals