80209C_MHW_850-1650-1850_02-2020_ENG_pag. 131
4.17.8. MSG.IN - Selecting the digital input message
Acronym Scrolling message Submenu Attributes
MSG.IN IN.DIG.1 (o IN.DIG.2 … IN.DIG.5) NUMBER OF SCROLLING MESSAGE AT
INPUT ACT
IN.DIG R W
The parameter shows and sets the number of the message assigned to activation of the digital input, i.e., the scrolling
message shown on the display.
For more information on scrolling messages, see paragraph “3.1.2.2. Scrolling messages” on page <?>.
If the parameter is set to “0” no message will be displayed when the digital input is activated.
The same message number can be assigned to different inputs.
Unit of measurement: Number identificativo del messaggio
Options: 0...25 (with LAnG=LANG1 or LANG2 or LANG3)
0…75 (with LAnG=NONE)