80209C_MHW_850-1650-1850_20-2020_ENG_pag. 38
Digital inputs
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
41
42
43
44
45
46
COM
IN1
IN2
IN3
IN4
IN5
GND
PNP Digital inputs
+12/24 V max 3,6 mA
2.5.6. Serial line
Serial Line
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
7
8
9
46
47
48
A (Data -)
B (Data +)
Serial line
RS485 2-wires
2.5.7. CT Inputs
Inputs CT1, CT2
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
36
35
34
33
32
CT1
~
~
CT2
~
~
Current transformer
50 mAac, 10 , 50/60 Hz
Second current transformer
for 2-phase / 3-phase load
2.5.8. Auxiliary input (AUX1)
Input TC
[with option auxiliary input = 1,available only if
the main input is configured Type TC]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
4
27
26
25
+
-
Available thermocouples:
J, K,R, S, T, C, D, B, E, L, L-GOST,
U, G, N,
Pt20Rh-Pt40Rh
ITS90 or custom linearization
Respect polarity
For extensions, use a
compensated cable
Inputs PT100/JPT100 - 2-wires connection
[with option auxiliary input = 1]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Attention:
with this type of connection the line
resistance can introduce measurement
error, we recommend that you use wires
of adequate screen.
Inputs PT100/JPT100 - 3-wires connection
[with option auxiliary input = 1]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Attention:
with this type of connection the
line resistance can introduce
measurement error, we recommend
that you use wires of adequate screen.
The resistance of the three wires must
be equal, the line resistance must be
less than 20 ohm.
Linear Inputs (V)
[with option auxiliary input = 1]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Linear input in direct voltage
0...60 mV Ri > 100 MΩ
Linear Inputs (V, I)
[with option auxiliary input = 1]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Linear input in direct voltage
0...1 V Ri > 400 KΩ
Linear input in direct current
0/4...20 mA, Ri = 50 Ω.
Linear Inputs (V)
[with option auxiliary input = 2 o 3]
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Linear input in direct voltage
0...5 V / 0...10 V Ri > 400 KΩ