EasyManuals Logo
Home>gefran>Temperature Controller>850

gefran 850 User Manual

gefran 850
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
80209C_MHW_850-1650-1850_20-2020_ENG_pag. 36
2.5.2. Power supply
Power supply
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
22
23
24
~
~
PWR
Standard:
100...240 VAC/VDC ± 10%
50/60 Hz, max 12W
Optional:
20...27 VAC/VDC ± 10%
50/60 Hz, max 12W
(*) ground connection for option
20...27 V AC/DC only
2.5.3. Main input (MAIN)
Input TC
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
6
5
4
3
2
1
+
-
Available thermocouples:
J, K,R, S, T, C, D, B, E, L,
L-GOST, U, G, N,
Pt20Rh-Pt40Rh
ITS90 or custom linearization
Respect polarity
For extensions, use a
compensated cable
Input PT100/JPT100 - -2 wires connection
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Attention:
with this type of connection the
line resistance can introduce
measurement error, we recommend
that you use wires of adequate.
Input PT100/JPT100 - 3 -wires connection
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
6
5
4
3
2
1
T
Attention:
with this type of connection the
line resistance can introduce
measurement error, we recommend
that you use wires of adequate.
The resistance of the three wires
must be equal, the line resistance
must be less than 20 ohm.
Linear input (V, I)
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Linear input in direct voltage
0...60 mV Ri > 100MΩ
0...1 V Ri > 100MΩ
Linear input in direct current
0/4...20mA, Ri = 50 Ω
Linear input (V)
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Linear input in direct voltage
0...5 V / 0...10 V Ri > 400kΩ
2.5.4. Output
Characteristics of outputs Out1, Out2, Out3, Out4 are de-
fined when the controller is ordered.
Output Out 1 - relay 5 A
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Relay 250 VAC, 5 A
Output Out 1 - logic
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Logic 24 V ±10%
(min 10 V a 20 mA)
Output Out 1 - continuous
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
4...20 mA Rout < 500 Ω
Output Out 2 – relè 5 A
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
12
11
10
9
8
7
37
38
39
40
41
42
6
5
4
3
2
1
43
44
45
46
47
48
36
35
34
33
32
31
30
29
28
27
26
25
Relay 250 VAC, 5 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran 850 and is the answer not in the manual?

gefran 850 Specifications

General IconGeneral
Brandgefran
Model850
CategoryTemperature Controller
LanguageEnglish

Related product manuals