EasyManuals Logo
Home>INVT>Control Systems>EC160

INVT EC160 User Manual

INVT EC160
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
User manual of EC160 elevator intelligent integrated machine EC160 configuration
9
No. Type Function name Function instruction Remarks
64
Vice control box
operation
With the same button and function with the
main control box, need to set F0_09 to 0.
Function
selection
65 Hand door control
To avoid short circuit of the lock, disconnect
the lock once before fast running and set
F0_01 to 1.
Function
selection
66
Others
LED display 2 digit, display floors and fault codes Standard
67 Floor displaying Dot matrix displaying
Standard
DC-03A
68
Running direction
displaying
Rolling displaying shows the running
direction.
Standard
DC-03A
69
Floor displaying
setting
Set the characters of floor displaying
through parameters.
Function
selection
70
Fault history
clearance
The system will record the latest 30 faults,
including the fault time, fault code, floor
information.
Standard
71
Error in internal
command cancel
Pressing the button twice can cancel the
internal command. The function is enabled
by setting F0_16 to 16.
Standard
72
Reverse automatic
number clearance
Select whether to clear the previous
reverse commands by F0_18 when the
elevator is arrived to the terminal floor or
the running direction is changed.
Function
selection
73
Failure diagnosis of
hoistway autotuning
The elevator can not run without correct
hoistway data.
Standard
74
Automatic car
height correction
The system will correct the position data at
the terminal door area and leveling switch
position according to the autotuning data.
Standard
75 Leveling adjustment Adjust the leveling precision. Standard
76
Current ramp
clearance
In the application of permanent magnet
synchronous motor, the maintenance
current is cleared through ramp to avoid
abnormal noise. Setting P5_12 can delay
current ramp clearance.
Standard