11. Use of High-speed Counters (C235 to C255)
11.1 Outline
The high-speed counters can count the signals to the general-purpose input terminals to the main unit or to
the high-speed input special adapters (options).
These two types of counters differ in the maximum response frequency and type of input signals to be
counted.
→ For details, refer to Section 11.2.
• General-purpose input terminals of main unit
Signals from an open collector transistor output can be input to the counters. The counters can count
signals of up to 100kHz (1-phase).
• High-speed input special adapters
Signals from a differential line driver output can be input to the counters. The counters can count signals of
up to 200kHz (1-phase).
Cautions for high-speed input special adapters
Do not use the same input number for both the high-speed input special adapter terminal and the main unit
terminal.
• When wiring the input numbers assigned to a high-speed input special adapter, do not wire the same input
number in main unit.
• When not wiring the input numbers assigned to a high-speed input special adapter, the main unit’s input
terminals can be used as general inputs.
High-speed input special adapters
FX
3U
-4HSX-ADP
Main unit
General-purpose input terminal block
X000 to X007
Rotary encoder, etc.
(Output form: Open collector transistor)
Rotary encoder
(Output form: Differential line driver)
1st unit : X000,X001,X002,X006
2nd unit : X003,X004,X005,X007
FX
3U
-48MR/ES
FX
3U
-48MFX
3U
ERROR
RUN
BATT
POWER
R
0312
IN
OUT
645
21
7
20 2422 23 2625
10 11 1312 161 4 15 17
27
0312 645
21
7
20 2422 23 2625
10 11 1312 161 4 15 17
27
Y12Y1 0 Y16Y14 Y2 2Y20 Y26 COM5
COM1
Y24Y6
Y4Y2Y0
Y7 Y11 Y13Y5
COM2
Y3
Y1
COM3 Y15 Y17COM4 Y2 3 Y25 Y27Y2 1
X5
X0
X1
X2
X3 X7
X11
X13
X40VS/S
N 24V
X6 X10 X12 X1 4 X16 X20
L
・
・・
・
・
X27X23 X25X15 X17 X 21
X24 X26X22
FX
3U
-48MR/ES
FX
3U
-48MFX
3U
ERROR
RUN
BATT
POWER
R
0312
IN
OUT
645
21
7
20 2422 23 2625
10 11 1312 161 4 15 17
27
0312 645
21
7
20 2422 23 2625
10 11 1312 1614 15 17
27
Y12Y1 0 Y16Y14 Y2 2Y20 Y26 COM5
COM1
Y24Y6
Y4Y2Y0
Y7 Y11 Y13Y5
COM2
Y3
Y1
COM3 Y15 Y17COM4 Y2 3 Y25 Y27Y2 1
X5
X0
X1
X2
X3 X7
X11
X13
X40VS/S
N 24V
X6 X10 X12 X1 4 X16 X20
L
・
・・
・
・
X27X23 X25X15 X17 X 21
X24 X26X22