5 - 16
5.3 Settings and Procedures before Operation
5
SETTINGS AND PROCEDURES BEFORE OPERATION
* 1 To write the parameters, connect the utility to the C Controller module with the write authority.
( Section 5.11, Section 9.1.3)
Figure 5.14 Flowchart for MELSECNET/H system configuration (Continued)
(To 1) on previous page)
3)
2)
Move the RUN/STOP/MODE switch of the C Controller
module from STOP to RUN, and check that the C
Controller module is in the RUN status (the RUN LED is
lit).
Check the operation status (e.g. errors) in the system
information of the C Controller setting utility.
Check the operation status (e.g. errors) in the system
information of the C Controller setting utility.
On the MELSECNET/H utility, check the operation status
(e.g. errors). (Module information, Error history monitor,
Other station monitor, etc.)
On the Device monitor utility, make sure that access can
be made to its own station or other stations.
Create and debug a user program using Tornado, and
register it to the C Controller module.
Write the set parameters from the <<Online operation>>
tab of the MELSECNET/H utility to the C Controller
module.
No
Yes
Is there no error?
(To 1) on previous page)
Operation
Set the switches of all CPU modules from STOP to RUN.
Check that all CPU modules are in the RUN status (the
RUN LED is lit).
On the MELSECNET/H utility, check the operation status
(e.g. errors). (Module information, Error history monitor,
other station monitor, etc.)
Create and debug a user program using Tornado, and
register it to the C Controller module.
On the Device monitor utility, make sure that access can
be made to its own station or other stations.
No
Yes
Is there no error?
Operation
Section 5.4 (2) and
user's manual of the
CPU module used
Reset CPU No.1.
(Reset operation makes the written parameters effective.)
Section 13.6 and user's
manual of the CPU
module used
Section 5.4 (1) and
user's manual of the
CPU module used
Section 9.4.2, 9.4.3,
9.4.4
*1
Section 5.4 (2)
Section 9.4.2, 9.4.3,
9.4.4
Section 9.5
Chapter 10
Section 9.4.5
Section 5.4 (1)
Section 13.6
Section 5.4 (2)
Section 9.4.2, 9.4.3,
9.4.4
Section 9.5
Chapter 10

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals