CHAPTER 26
Configuring Gigabit-Backplane Physical
Interface Modules
•
1-Port Clear Channel DS3/E3 GPIM Basic Configuration on page 221
•
2-Port 10-Gigabit Ethernet XPIM Basic Configuration on page 223
•
8-Port Gigabit Ethernet SFP XPIM Basic Configuration on page 227
•
8-Port Serial GPIM Basic Configuration on page 230
•
16-Port Gigabit Ethernet XPIM Basic Configuration on page 232
•
24-Port Gigabit Ethernet XPIM Basic Configuration on page 233
•
Dual CT1/E1 GPIM Basic Configuration on page 235
•
Quad CT1/E1 GPIM Basic Configuration on page 238
1-Port Clear Channel DS3/E3 GPIM Basic Configuration
To enable the 1-Port Clear Channel DS3/E3 GPIM installed on the SRX Series Services
Gateway, you must configure the basic settings for the PIM. You can perform the
configuration tasks for this using either the J-Web interface or the CLI.
•
Using the CLI on page 221
Using the CLI
To perform basic configuration for the 1-Port Clear Channel DS3/E3 GPIM and to configure
network interfaces for the services gateway with the CLI:
•
Verify that the 1-Port Clear Channel DS3/E3 GPIM is installed on the services gateway:
show chassis hardware
root@srx650r03> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis AJ2210AA0064 SRX650
Midplane REV 09 710-023875 AABJ4077
System IO REV 08 710-023209 AABK2897 SRXSME System IO
Routing Engine REV 18 750-023223 AABJ8853 RE-SRXSME-SRE6
FPC 0 FPC
PIC 0 4x GE Base PIC
FPC 2 REV 03 750-023873 TV4286 FPC
FPC 5 REV 10 750-023810 AABE1433 FPC
221Copyright © 2015, Juniper Networks, Inc.