Trigger setups Trigger on nth Event (Horizontal Delay off)
NOTE. On MSO/DPO5000 Series instruments, trigger on B events is available only for Edge trigger.
2. Select the A–>B Seq tab; then click Trig on nth Event.
3. Set the Horizontal Delay Mode button to On.
4. Select the number of B events with the Trig Event control.
5. Use the Hori
z Delay control to delay the acquisition relative to the B event.
6. Adjust the Ref Point and B Trig Level controls as necessary.
Behavior
When you s
elect Trig on nth Event, the instrument looks for the trigger conditions specified by the A event.
After the A event arms the trigger system, the instrument looks for a specificnumberofBeventsbefore
triggering. The instrument then delays the acquisition for the amount of time specified by the Horiz Delay
control. After the delay time has expired, the instrument displays the data.
What do you want to do next?
Learn more about Horizontal Delay. (see page 839)
Learn
more about other trigger types.
(see page 386)
Return to the Trigger Setup control window. (see page 385)
Trigger on nth Event (Horizontal Delay Off). (see page 453)
Trigger on nth Event (B-Event Scan). (see page 455)
Trigger on nth Event (B-Event Scan and Horizontal Delay On). (see page 456)