6.2 BASIC START UP MENUS
ThefollowingDRIVESTATUS,STARTUPandTUNINGallowabasiccommissioningofthedrive.
note ! Theparametersinthesemenusareavailableinothermenus.
SeeStartupprocedureonchapter5.3forcommissioninginformation.
DRIVE STATUS
Menudisplayedatpowerup.
StatusparametersofthedriveareavailableandRamp ref 1parameterforbasicspeedreferencewithramptime.
START UP
Inthismenuthestartupsequencingisavailable.
First basic setting
Speed base value Speed base valueisdenedbytheunitinthefactorfunctionspecied.Itisthereference
valueforallthespeedreferencevalues(referencevalues,adaptivespeedregulation)
givenasapercentage,andcorrespondsto100%ofthespeed.Changingthisparameter
isonlypossiblewhenthedriveisdisabled(Enable drive=Disable).Thespeedbase
valuedoesnotdenethemaximumpossiblespeed,whichinsomecasescanbeformed
fromtheadditionofseveralreferencevalues.ThisisdenedwithSpeedmaxamount.
Nom ux curr Driveeldcurrentvalue.
Speed-0 f weak Enablestheeldeconomyatzerospeed.
Acc / Dec ... Accelerationanddecelerationramptimesettingonthespeedreference.(seechapter
6.6.1formoredetails).
Motor data
Motorplatedata:
Motor nom ux MotoreldcurrentinAmps.
Flux reg mode Fieldregulatormode.
Full load curr NominalmotorcurrentinAmps.
Motor max speed Maximummotorspeedvalue
Max out voltage Maximumarmaturevoltagevalue