—————— TPD32-EV ——————
360
6.18 DRIVECOM
TheDRIVECOMprole#21“Powertransmission,”denesthebehaviorofthedriveifthisisoperatedviatheINTER-
BUS-Seldbus.TheDRIVECOMmenuoftheTPD32-EVconverterprovidesfunctionsthatweredenedinthe
abovestandardsandwhicharerequiredtooperateamotorwiththeconverter.
TheTPD32-EVconverters,however,haveaconsiderablygreaterrangeoffunctionsthanisdenedhere.Apart
fromafewexceptionstheparametersprovidedinthismenuaredescribedsomewhereelseindetail.Wewill
thereforerestrictthisdescriptiontotheParametersfunction.Seesection10,“Parameterlist”andtheabove
standardforfurtherinformationontheparameters.WhenoperatingfromaBus,theparametersintheDrivecom
groupcanalsobeaccessedusingtheformatandindexspeciedintheabovestandard.
6.18.1 Control word, status word, malfunction code
DRIVECOM
[57] Malfunctioncode
[55] Controlword
[56] Statusword
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Malfunction code
57
Control word
55 0 65535
Status word
56 0 65535
Malfunction code MalfunctioncodeaccordingtoDRIVECOMspecication(Mandatoryfunctions)
Thecodedisplayedindicatesaparticularfailure.Themeaningoftheindividualfailures
concernedisdescribedinthesectionProgrammableAlarms.
1001h Unknown alarm
2300h Overcurrent
4210h Heatsink overtemperature
5000h Hardware
5100h Failure supply
5211h Ud measurement
6110h DSP error
6120h Interrupt error
7301h Speed feedback loss
9000h External fault
4310h Motor overtemperature
3330h Field loss
8110h Bus loss
7510h Hw opt 1 failure
7400h Hw opt 2 failure
3120h Undervoltage
3310h Overvoltage
9009h Enable seq err
9090h Brake error
7120h I2t motor overload error
3320h Over Speed error
3140h Mains frequency error
2310h I2t drive overload error
8100h SSC Error
8101h Shorted SCR
8102h Open SCR
Thecodeandthealarmaredisplayedinplaintextintheeventofafailure.Thecode
isgiveninhexadecimalformat.
Control word ControlwordaccordingtoDRIVECOMspecication(Mandatoryfunctions)
Status word StatuswordaccordingtoDRIVECOMspecication(Mandatoryfunctions).
Newfunction,startingfrom:FirmwareStandard=10.08A(TPD32-EV),FirmwareFC-
200V=10.25AandFirmwareFC-500V=10.26A(TPD32-EV-FC).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran TPD32-EV-...-4B and is the answer not in the manual?

gefran TPD32-EV-...-4B Specifications

General IconGeneral
Brandgefran
ModelTPD32-EV-...-4B
CategoryDC Drives
LanguageEnglish

Related product manuals