2.2 UPON DELIVERY INSPECTION PROCEDURES
Storage, Transport
AhighdegreeofcareistakeninpackingtheconvertersoftheTPD32-EVseriesandpreparingthemfordelivery.
Theyshouldonlybetransportedwithsuitabletransportequipment(seeweightdata).Observetheinstructions
printedonthepackaging.Thisalsoapplieswhenthedeviceisunpackeduptowhenitisinstalledinthecontrol
cabinet.
Ondeliverycheckthefollowing:
- thepackagingforanyexternaldamage
- whetherthedeliverynotematchesyourorder.
Openthepackagingwithsuitabletools.Checkwhether
- anypartsweredamagedduringtransport
- thedevicetypecorrespondstoyourorder
Intheeventofanydamageorofanincompleteorincorrectdeliverypleasenotifythesalesofcesresponsible
immediately.
Thedevicesshouldonlybestoredindryroomswithinthetemperaturerangesspecied.
note! Acertaindegreeofmoisturecondensationispermissibleifthisarisesfromchangesintem-
perature(seesection3.1,“PermissibleAmbientConditions”)Thisdoesnot,however,apply
whenthedevicesareinoperation.Ensurealwaysthatthereisnomoisturecondensationin
devicesthatareconnectedtothepowersupply!
2.2.1 Device setting
TheconvertersoftheTPD32-EVseriescanoperateconnectedtoanACinputthree-phasevoltagefrom230Vto
690V.Insidethisvoltagerangethedevicesettingiscarriedoutonthebasisofthemotorratedcurrent.Therefore
theconverterratedcurrentmustbehigherorthesameasthemotorratedone.
Ifanoverloadisnecessary,thesettingiscarriedoutaccordingtotheexamplementionedinsection6.14.6,
“Overloadcontrol”,sothattheovercurrentmustnotbesuppliedinacontinuativewayfromthetypeofthe
chosenconverter.
note! Areductionfactorshouldbeconsiderediftheconverterisinstalledataltitudesofover3,300
feet(1000m)abovesealevelandathighertemperatures(seesection3.1,“Permissibleambi-
entconditions”).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran TPD32-EV-...-4B and is the answer not in the manual?

gefran TPD32-EV-...-4B Specifications

General IconGeneral
Brandgefran
ModelTPD32-EV-...-4B
CategoryDC Drives
LanguageEnglish

Related product manuals