Enable spd=0 I Enabled TheIcomponentofthespeedregulatorissetto0whenthe
referencevalueandtheactualvalue=0.Thedrivecontrolis
thenonlyproportional.TheIcomponentisenabledwhena
referencevalueisenteredtorestartacceleration.
Disabled Disablethefunction.
Enable spd=0 R Onlyeffectiveif Enable spd=0 P isenabled.
Enabled Theproportionalgain,equaltoSpd=0 Pgainatzerospeed,
isequaltoSpeed Pwhenthespeedreferencebecomeshigher
thanthevaluedenedbyRef 0 level.
Disabled Theproportionalgain,equaltoSpd=0Pgainatzerospeed,is
equaltoSpeed Pwhenthespeedreferenceortheactualspeed
becomehigherthanthevaluedenedbyRef 0level.
Enable spd=0 P Enabled Whenbothreferencevalueandactualvalue=0,thepropor-
tionalSpd=0 Pgaincomponentisactiveafterthedelaytime
denedbySpeedzerodelay.
Disabled Thespeedregulatoralsokeepsitsproportionalgaincomponent
whenthedriveisatastop.
Spd=0 P gain Proportionalgainofthespeedregulator,thatisonlyactivewhenbothreferencevalue
andactualvalue=0,andiftheEnable spd=0 Pfunctionhasbeenenabled.
Ref 0 level Switchthresholdforspeedzerologic.Denedinthedimensionspeciedinthefactor
function.Speedsbelowthisthresholdaredenedaszero.
6.7.3 Speed up
SPEED REGULAT
Speed up
[445] Speedupgain[%]
[446] Speedupbase[ms]
[447] Speeduplter[ms]
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Speed up gain [%]
445 0.00 100.00 0.00 0.00
-
Speed up base [ms]
446 0 16000 1000 1000
-
Speed up lter [ms]
447 0 1000 0 0
-
TheSpeed-upfunctionisusedinordertoavoidoscillationsinpresenceofloadswithahighmomentofinertia.
Itismadeupofaderivativepartinthespeedfeedbackcircuit,whichallowstoincreasetheintegralgainofthe
speedregulator.Itisalsousefulincaseofcyclicalnonconstantloadsonthemotor(ex.cams).Thefeedback
appliedtothespeedregulatorismadeoftwocomponents:
- themotorspeed
- theoutputsignalfromtheSpeedupfunction
ThisfunctionismutuallyexclusivetotheInertia/loss compfunction,ThisselectionmustbedoneviatheAux
spd fun sel [1016]parameter.(SPEEDREGULATmenu).Seesection6.7.1Speedregulator.
Speed up gain SpeedupfunctiongainasapercentageofSpeed up base
Speed up base Speedupfunctionmax.gain.Thedenedvaluecorrespondsto100%oftheSpeed up
gainparameter.
Speed up lter TimeconstantofthelterbelongingtotheDpartoftheSpeedupfunction.
Seeexamplegure5.3.7.3.and5.3.7.4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran TPD32-EV-...-4B and is the answer not in the manual?

gefran TPD32-EV-...-4B Specifications

General IconGeneral
Brandgefran
ModelTPD32-EV-...-4B
CategoryDC Drives
LanguageEnglish

Related product manuals