—————— TPD32-EV ——————
498
A2.7 Parameter changes
ThissectionspeciesonlythedifferencesbetweentheversionTPD32-EV-FCparameterslistandthestandard
TPD32-EVversiondescribedinchapter10.
EliminatedMenu:
FluxRegulation
RegParameters/PercentValues/FluxRegulation
RegParameters/PercentValues/VoltageReg
RegParameters/BaseValues/FluxRegulation
RegParameters/BaseValues/VoltageReg
Conguration/ProgAlarms/FieldLoss
Conguration/ProgAlarms/SpeedFbkloss
Eliminated parameters:
Par91-FluxP
Par92-FluxI
Par97-FluxPbase
Par98-FluxIbase
Par280-Motornomux
Par374-Nomuxcurr
Par456-Fluxweakspeed
Par467-Fluxcurrentmax
Par468-Fluxcurrentmin
Par474-FLrestarttime
Par475-FLHoldofftime
Par480-SLHoldofftime
Par493-VoltageP
Par494-VoltageI
Par495-VoltagePbase
Par496-VoltageIbase
Par916-Ieldcnst40
Par917-Ieldcnst70
Par918-Ieldcnst90
Par919-Setux/if
Par921-Outvltlevel
Par201-2B+E
Par469-Fluxregmode
Par471-FLLatch
Par472-FLOkrelayopen
Par473-FLActivity
Par477-SLOkrelayopen
Par478-SLActivity
Par497-Enableuxreg
Par498-Enableuxweak
Par499-Speed-0fweak
Par234-Fluxcurrent
Par351-Fluxcurrent(A)
Par500-Fluxreference
Par452-RLSearch
Par587-Eint
Renamedparameters/selections:
START UP \ MOTOR DATA
CONFIGURATION
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Fulleldcurr[A]
179 Float 0.1 S S
ü
R/W - -
DRIVE STATUS
MONITOR \ MEASUREMENTS
CURRENT REGULAT
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Fieldcurrent[%]
199 I16
ü
R - -
I/O CONFIG \ ANALOG OUTPUTS \ ANALOG OUTPUT 1 ... 4
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Selectoutput1...4
Field current
66...69 U16 0 96 -
ü
R/Z
16
- -