46
FX3UC Series Programmable Controllers
User’s Manual - Hardware Edition
1 Outline
1.6 System overall configuration
1.6 System overall configuration
Products connectable to the FX3UC PLC are classified into the groups to as shown below.
For model names of products classified into the and groups, refer to "1.11 Number of input/output
occupied points and 5V DC current consumption of each model".
A G
C D
Group
Group
Group
Special
adapter
Expansion
board
extension
I/O
Special
extension
I/O
FX
2NC
FX2NC-CNV-IF
FX
3UC-1PS-5V
FX
3UC-1PS-5V
FX
3UC-1PS-5V
FX
3UC-1PS-5V
(FX3UC/FX2NC Series)
Either
(FX
3U/FX2N/FX0N Series)
Range to be covered by main unit
I/O
FX
2N
I/O
FX
0N
Special
FX
3UC
function
Special
FX
2N
FX3U,
function
Special
FX
2NC
function
Special
FX
0N
function
I/O
FX
2NC
I/O
FX
2N
I/O
FX
0N
Special
FX
3UC
function
Special
FX
2N
FX3U,
function
Special
FX
2NC
function
I/O
FX
2NC
I/O
FX
2NC
Special
FX
3UC
function
Special
FX
3UC
function
Special
FX
2NC
function
Special
FX
2NC
function
I/O
FX
2NC
Special
FX
3UC
function
Special
FX
2NC
function
Special
FX
0N
function
I/O
FX
2N
I/O
FX
0N
Special
FX
2N
FX3U
function
Special
FX
0N
function
Special adapter
(Analog)
Special adapter
(communication)
Expansion board
(Only FX
3UC-32MT-LT)
FX
3UC Main unit
Group
Remote
I/O
Remote
I/O
Remote
I/O
Remote
I/O
(Only FX
3UC-32MT-LT)
GOT
Programming tool
FX
3U/FX3UC Option
FX
3UC
/FX
2NC
/FX
3U
/FX
2N
/FX
0N
Series extension devices (example)
Range to be covered by
main unit
Range to be covered by
main unit
Range to be covered by
FX
3UC-1PS-5V
The power supply for the built-in CC-Link/LT
module in the FX
3UC-32MT-LT can connect
remote I/O stations whose total current
consumption is 350 mA or less.
A power supply adapter for CC-Link/LT, etc.
is required when the power supply is
insufficient.
For details, refer to the Manual (CC-Link/LT).
FX2NC-CNV-IF
FX
3UC-1PS-5V
: FX
3U/FX2N/FX0N Series extension equipment can be
connected.
: FX
3UC/FX2NC Series extension equipment or
FX
3U/FX2N/FX0N Series extension equipment can be
connected.
Connection constructed using only the built-in power supply
(FX3U/FX2N/FX0N Series extension)
Connection when the built-in power supply is insufficient
(FX3UC/FX2NC Series extension)
Connection when the built-in power supply is insufficient
Range to be covered by
FX
3UC-1PS-5V (1st unit)
Range to be covered by
FX
3UC-1PS-5V (2nd unit)
To FX
3UC-1PS-5V (2nd unit)
FX3U-4AD-ADP
FX
3U-4DA-ADP
FX
3U-4AD-PT-ADP
FX
3U-4AD-TC-ADP
FX
3U-232ADP(-MB)
FX
3U-485ADP(-MB)
FX
3U-232-BD
FX
3U-422-BD
FX
3U-485-BD
FX
3U-USB-BD
FX
3U-CNV-BD