1.9 Calculation of 5V DC power supply capacity (current consumption)
Confirm the current consumption using the following procedures.
When the main unit built-in power supply is insufficient, add an extension power supply unit (FX
3UC-1PS-5V)
in accordance with the necessity.
1) Calculating the current in extension equipment that can receive power from the main unit built-in power
supply.
Check whether the current consumption of extension equipment to be connected is not more than the
capacity of the main unit built-in power supply.
2) Calculating the current in extension equipment that can receive power from the extension power supply
unit (FX
3UC-1PS-5V)
a) When only FX
3UC/FX2NC Series units are connected for extension:
b) When FX
3UC, FX2NC, FX3U, FX2N and FX0N Series equipment are connected for extension
For connection including the FX
3U, FX2N or FX0N Series extension equipment, the FX2NC-CNV-IF or
FX
3UC-1PS-5V is required:
When the capacity of the main unit built-in power
supply is insufficient, connect an extension power
supply unit (FX
3UC-1PS-5V) .
Select , or as and and
proceed to 2).
FX3UC Main unit
Special adapter
Expansion board
GOT
Programming tool
I/O extension
devices
FX3UC Main unit
FX3UC-1PS-5V
FX3UC special function
FX
2NC I/O
FX
2NC special function
Special function
devices
Proceed to "2) FX
3UC-
1PS-5V" below.
Calculate the current consumption
of the GOT/programming tool
connected to the FX
3U-422-BD.
FX
3UC-16MT/: 600mA
FX
3UC-32MT/: 560mA
FX
3UC-64MT/: 480mA
FX
3UC-96MT/: 400mA
FX
3UC-32MT/: 350mA
mA mA mA
mA
I/O extension
devices
Special function
devices
FX3UC-1PS-5V
FX
2NC I/O
FX
3UC special function
FX
2NC special function
Proceed to
1) above.
When the capacity is still insufficient:
Connect one more extension power supply unit (FX
3UC-1PS-5V) , and examine the
configuration of the remaining extension equipment.
1A(1000mA)
mA mA
When there are FX3UC or FX2NC Series extension equipment ,
or , connect them first, and then connect the FX
2NC-CNV-IF.
When the capacity is still insufficient:
Adopt the connection configuration shown in a) above (but the FX
2NC-CNV-IF is not allowed), connect
the extension power supply unit (FX
3UC-1PS-5V) , and then examine the entire configuration.
I/O extension
devices
Special function
devices
FX3UC-1PS-5V
FX
2NC-CNV-IF
FX
2N I/O
FX
0N I/O
FX
3U/FX2N special function
FX
0N special function
FX
3UC special function
FX
2NC special function
FX
2NC I/O
Proceed to
1) above.
mA
1A(1000mA)