EasyManuals Logo
Home>Tektronix>Test Equipment>DPO70000C/DX Series

Tektronix DPO70000C/DX Series User Manual

Tektronix DPO70000C/DX Series
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #473 background imageLoading...
Page #473 background image
Trigger setups Trigger After Time (Horizontal Delay off)
The following screen appears on MSO/DPO5000 Series instruments:
To use
1. Set up the A Event and B Events from their individual tabs.
2. Select the A–>B Seq tab; then click Trig After Time.
3. Click to set the Horizontal Delay Mode button to Off.
4. Select the trigger delay time with the Trig Delay control.
5. Adjust the Horiz Position and B Trig Level controls as necessary.
Behavior
When you select Trig After Time, the instrument looks for the trigger conditions specied by the A
event. After the A event arms the trigger system, the instrument triggers on the n ext B event that occurs
after the time specied by the Trig Delay control.
What do you want to do next?
Learn m ore about other trigger types. (see page 386)
DSA/DPO70000D, MSO/DPO/DSA70000C, DPO7000C, and MSO/DPO5000 Series 451