SECTION 88 - ACCESSORIES
88-2
Op. 88 100
GENERAL INFORMATION
ADAPTING ATTACHMENTS REQUIRING
12V ELECTRICAL POWER
There are important rules that must be followed when
adapting attachments that require 12 volt electrical
power. Proper wiring of electrical devices and power
and ground connections is very important to prevent
other electrical component damage. Attaching elec-
trical connections to locations other than recom-
mended may allow electric current to feed back
through the EIC board, creating false EIC board
readings and warnings, or causing EIC board dam-
age or failure.
1. ALWAYS FOLLOW the instructions for New Hol-
land kit installation to ensure proper function and
operation.
2. NEVER CONNECT an electrical device to any
wires, fuses, switches or grounds inside the cab
area. This includes any terminals of the ignition
switch, fuse panel, or ground terminal.
3. NEVER INSTALL an electrical device, music ra-
dio, two-way radio, or unapproved New Holland
attachment into the cab area.
4. ONLY USE the 12-volt accessory power outlet
for attachments requiring less than 10 amps. The
accessory outlet is connected to the engine fuse/
relay panel and protected with a 15 amp fuse.
1
5. ALWAYS CONNECT new electrical attachments
to the engine fuse/relay panel, 1, and connect the
grounds to the engine bell housing. USE ONLY
vacant connections and fuses not in use for spe-
cified attachments.
2