RL78/G15 CHAPTER 13 SERIAL INTERFACE IICA
R01UH0959EJ0110 Rev.1.10 Page 536 of 765
Mar 7, 2023
13.5.5 Stop condition
A stop condition is generated when the SDAA0 pin changes from the low to the high level while the SCLA0 pin is at the
high level.
A stop condition is a signal that the master generates to the slave when serial transfer has been completed. A stop
condition can be detected when the device is used as a slave.
Figure 13-18. Stop Condition
SCLA0
SDAA0
H
A stop condition is generated when bit 0 (SPT0) of IICA control register 00 (IICCTL00) is set to 1. When the stop
condition is detected, bit 0 (SPD0) of IICA status register 0 (IICS0) is set to 1 and INTIICA0 is generated when bit 4
(SPIE0) of the IICCTL00 register is set to 1.