12.6.3 Calculating Baud Rate
(1) Baud rate calculation expression
The baud rate for UART (UART0) communication can be calculated by the following expressions.
(Baud rate) =
{
Operation clock (f
MCK
) frequency of target channel
}
÷
(
SDRmn[15: 9] + 1
)
÷ 2[bps]
Caution Setting serial data register mn (SDRmn) SDRmn[15:9] = (0000000B, 0000001B) is prohibited.
Remark 1. When UART is used, the value of SDRmn[15:9] is the value of bits 15 to 9 of the SDRmn register
(0000010B to 1111111B) and therefore is 2 to 127.
Remark 2. m: Unit number (m = 0), n: Channel number (n = 0), mn = 00
The operation clock (f
MCK
) is determined by serial clock select register m (SPSm) and bit 15 (CKSmn) of serial mode
register mn (SMRmn).