3C-4 Transfer: Motor-Shift Type (Transfer with Shift Actuator)
Operation
Condition
Indicator Buzzer
Differential
lock
indicator
OFF —
• Ignition switch is OFF.
• Transfer is at 4H/N position.
ON —
• Within 2 seconds after ignition switch is turn ON (checking
indicator operation).
• Transfer is at 4H-lock/4L-lock position.
Flashes at 0.25
seconds for 3
times, at intervals
of 20 seconds.
Sounds at 1
second at
intervals of 20
seconds.
• The transfer shift position is different for transfer switch.
Flashes at
intervals of 0.25
seconds
continuously
— • 4WD control module detects DTC of 4WD control system.
Flashes at
intervals of 0.5
seconds
continuously
—
• Transfer is shifting from 4H to 4H-lock.
• Transfer is shifting from 4H-lock to 4H.
• Transfer could not complete shifting to 4H-lock.
4L indicator
OFF —
• Ignition switch is OFF.
• Transfer is at 4H-lock/N position.
ON —
• Within 2 seconds after ignition switch is turn ON (checking
indicator operation).
• Transfer is at 4L-lock position.
Flashes at 0.25
seconds for 3
times, at intervals
of 20 seconds.
Sounds at 1
second at
intervals of 20
seconds.
• The transfer shift position is different for transfer switch.
Flashes at
intervals of 0.25
seconds
continuously
— • 4WD control module detects DTC of 4WD control system.
Flashes at
intervals of 0.5
seconds
continuously
—
• Transfer is shifting from 4H-lock to 4L-lock.
• Transfer is shifting from 4L-lock to 4H-lock.
• Transfer could not complete shifting to 4L-lock.
N indicator
OFF —
• Ignition switch is OFF.
• Transfer is at 4H/4H-lock/4L-lock position.
ON —
• Within 2 seconds after ignition switch is turn ON (checking
indicator operation).
• Transfer is at N position.
Flashes at 0.25
seconds for 3
times, at intervals
of 20 seconds.
Sounds at 1
second at
intervals of 20
seconds.
• The transfer shift position is different for transfer switch.
Flashes at
intervals of 0.2
seconds
continuously
— • 4WD control module detects DTC of 4WD control system.
Flashes at 0.5
seconds
continuously
— • Transfer could not complete shifting to N.
——
Sounds at 0.2
seconds for 2
times, at intervals
of 3 seconds.
• Transfer is at N position.