132 Program features
User load curve
The user can specify a load curve (motor torque as a function of frequency) for
supervision. The curve is defined by five points. Supervision can be set for the torque
dropping below the underload curve, exceeding the overload curve, or both.
A fault is generated if the torque has been out of the allowed area for longer than the
user-defined time limit. An alarm is generated if the torque has been out of the
allowed area for longer than the half of the user-defined time limit.
Settings
1805 Timed function status indicated through digital output DO
4027 Timed PID1 parameter set 1/2 selection
4228 Timed external PID2 activation
Parameter Additional information
Group 37: User load curve User load curve settings
Parameter Additional information
Overload area
Underload area
Allowed operating area
Motor torque (%)
Output
frequency (Hz)
Freq. 2 Freq. 1 Freq. 3 Freq. 4 Freq. 5
Torq ue
high 1
Torque
high 2
To r q u e
high 3
Torq ue
low 1
Torque
low 2
To r q u e
low 3
To r q u e
high 4
Torq ue
low 4
To r q u e
high 5
To r q u e
low 5

Table of Contents

Other manuals for ABB ACS320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS320 and is the answer not in the manual?

ABB ACS320 Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
IP RatingIP20
Frame SizeR1 to R3
Enclosure RatingIP20
Frequency Range0 to 500 Hz
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overload, Short circuit, Ground fault, Overtemperature
Fieldbus CommunicationModbus RTU, PROFIBUS DP, CANopen
Communication InterfacesRS485
Operating Temperature-10 to +50 °C (14 to 122 °F)
Storage Temperature-40°C to +70°C
HumidityLess than 95% (non-condensing)
Supply Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)