398 Technical data
Materials
Drive enclosure PC/ABS 2 mm, PC+10%GF 2.5…3 mm and PA66+25%GF
1.5 mm, all in color NCS 1502-Y (RAL 9002 / PMS 420 C)
hot-dip zinc coated steel sheet 1.5 mm, thickness of coating 20
micrometers
extruded aluminium AlSi.
Package Corrugated cardboard.
Disposal The drive contains raw materials that should be recycled to preserve
energy and natural resources. The package materials are
environmentally compatible and recyclable. All metal parts can be
recycled. The plastic parts can either be recycled or burned under
controlled circumstances, according to local regulations. Most
recyclable parts are marked with recycling marks.
If recycling is not feasible, all parts excluding electrolytic capacitors
and printed circuit boards can be landfilled. The DC capacitors
contain electrolyte, which is classified as hazardous waste within the
EU. They must be removed and handled according to local
regulations.
For further information on environmental aspects and more detailed
recycling instructions, please contact your local ABB distributor.
Applicable standards
The drive complies with the following standards:
IEC/EN 61800-5-1:
2003
Electrical, thermal and functional safety requirements for adjustable
frequency a.c. power drives
IEC/EN 60204-1:
2006
Safety of machinery. Electrical equipment of machines. Part 1:
General requirements. Provisions for compliance: The final
assembler of the machine is responsible for installing
- an emergency-stop device
- a supply disconnecting device.
IEC/EN 61800-3:
2004
Adjustable speed electrical power drive systems. Part 3: EMC
requirements and specific test methods
UL 508C UL Standard for Safety, Power Conversion Equipment, third edition

Table of Contents

Other manuals for ABB ACS320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS320 and is the answer not in the manual?

ABB ACS320 Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
IP RatingIP20
Frame SizeR1 to R3
Enclosure RatingIP20
Frequency Range0 to 500 Hz
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overload, Short circuit, Ground fault, Overtemperature
Fieldbus CommunicationModbus RTU, PROFIBUS DP, CANopen
Communication InterfacesRS485
Operating Temperature-10 to +50 °C (14 to 122 °F)
Storage Temperature-40°C to +70°C
HumidityLess than 95% (non-condensing)
Supply Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)