Starting/turning off the engine for driving
4.2 Turning off the engine
4 - 26 3 112 993 en Operating manual GMK 6400
12.07.2013
4.2.2 Using the emergency stop switches
Emergency stop switch
Four emergency stop switches are provided
for an emergency:
• Press an emergency stop switch (1), (2) or
(3). The switch engages.
The engine shuts down.
H
If an air intake inhibitor is present, it is triggered.
H
Do not operate the emergency stop switch to turn off the engine in normal
operation. Only operate the emergency stop switch in an emergency situa-
tion.
Resetting the
emergency stop
switch
You can only restart the engine after you have reset the emergency stop
switch.
• Switch off the ignition.
• Turn the actuated emergency stop switch until it disengages again.
If an air intake inhibitor is fitted, it must be loosened;
à Releasing the air
intake inhibitor
, p. 4 - 27.
1 On the carrier
2 On the hand-held control
3 In the crane cab

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK 6400 and is the answer not in the manual?

Manitowoc GROVE GMK 6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK 6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals