Rigging work
12.7 Rigging/unrigging the counterweight
12 - 82 3 112 993 en Operating manual GMK 6400
12.07.2013
12.7.9 Making/breaking the electrical connection
.
Establishing
• Remove plug (2) from socket (1) and insert it
into socket (3).
• Cover the socket (1) with the cap.
Disconnecting The connection must be separated before lifting the 15-t base plate from the
carrier.
• Remove plug (2) from socket (3) and insert it
into socket (1).
• Cover the socket (3) with the cap.
S
Risk of malfunction in the superstructure electronics!
Always turn off the ignition in the crane cab before you establish or break
the electrical connection. This prevents malfunctions and error messages
in the superstructure electronics.