No. Parameter
mask
Parameter
internal
Data type Meaning
12 <_AMODE> INT Alternative mode
UNITS: Form-truing selection, new/continue
1 = New
2 = Continue
TENS: Select form-truing allowance
0 = From the rough contour to the
lowest point of the contour
1 = From the rough contour to the
highest point of the contour
13 <S_FW> REAL Clear angle of the dressing tool
14 <S_HW> REAL Holder angle of the dressing tool
3.25.1.33 CYCLE782 - adjust to load
Note
To use CYCLE782, a license is required for the option "Intelligent load adjustment":
Syntax
CYCLE782(<S_MODE>, <S_TESTAXIS>, <S_VALUE>)
Work preparation
3.25 Programming cycles externally
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 1091