Parameter
No. Parameter
mask
Parameter
internal
Data type Meaning
1 <_LEVEL> INT Level
0 = Main level
1 = 1st sublevel
2 <_SP> INT Spindle
0 = No spindle
1 = Main spindle
2 = Counterspindle
3.25.1.55 GROUP_ADDEND - End of trial cut addition
Syntax
GROUP_ADDEND(<_LEVEL>, <_SP>)
Parameter
No. Parameter
mask
Parameter
internal
Data type Meaning
1 <_LEVEL> INT Level
0 = Main level
1 = 1st sublevel
2 <_SP> INT Spindle
0 = No spindle
1 = Main spindle
2 = Counterspindle
3.25.1.56 Supplementary conditions
Technology scaling in cycle screen forms
When the technology scaling is active, the simplified input can be selected for various cycle
screen forms, in which only the most important cycle parameters are displayed
For example, the simplified input can be selected for the following cycle screen forms:
Technology Cycle screen form
Drilling Deep-hole drilling
Tapping
Milling Rectangular pocket
Contour milling: Pocket
Work preparation
3.25 Programming cycles externally
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 1153