Menu 12
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
226 Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
Open-loop
Figure 5-20 Open-loop brake function
Figure 5-21 Open-loop brake sequence
The brake control functions are provided to allow well co-ordinated operation of an external brake with the drive. While both hardware and
software are designed to high standards of quality and robustness, they are not intended for use as safety functions, i.e. where a fault or
failure would result in a risk of injury. In any application where the incorrect operation of the brake release mechanism could result in injury,
independent protection devices of proven integrity must also be incorporated.
WARNING
4.01
Current
magnitude
Upper current
threshold
Lower current
threshold
12.42
12.43
+
_
5.01
Output
frequency
Brake release
frequency
Brake apply
frequency
12.44
12.45
+
_
+
_
1.11
Reference
on
LAT
10.02
Drive
active
Post-brake
release
delay
12.47
Pre-brake
release
delay
12.46
12.40
Brake
release
Ramp
hold
2.03
Brake
controller
enable
12.41
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
i
o
r
LAT
input
reset
output
If the reset input is 1, the output is 0.
If the reset input is 0, the output
latches at 1 if the input is 1.
i
r
o
2
3
8.12
8.17
8.22
8.27
8.32
T25 digital
I/O 2 invert
Relay source
invert
T25 digital I/O 2
source / destination
Relay source
T25 digital I/O 12
output select
12
3
465
Pr Output frequency
5.01
Pr Reference on
1.11
Pr Brake release
12.40
Pr Ramp hold
2.03
Pr Drive active
10.02
Pr Current magnitude
4.01
1. Wait for upper current threshold and brake release frequency
2. Pre-brake release delay
3. Post-brake release delay
4. Wait for brake apply frequency
5. Wait for zero frequency
6. 1s delay as phase 2 of stopping sequence (Pr =1,2 or 3)
6.01
Pr Brake release frequency
12.44
Pr Brake apply frequency
12.45
Pr
12.46
Pr
12.47
Pr Upper current threshold
12.42

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson unidrive sp and is the answer not in the manual?

Emerson unidrive sp Specifications

General IconGeneral
BrandEmerson
Modelunidrive sp
CategoryController
LanguageEnglish

Related product manuals