Menus 15 to 17
SM-Resolver
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
272 Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
5.17.2 SM-Resolver
The Solutions Module checks for various errors as shown below.
Table 5-14 Solutions Module error status values for the SM-Resolver
+ This trip can be enabled/disabled by Pr x.17.
Figure 5-28 SM-Resolver logic diagram
Error code Reason for error
0 No fault detected
1 Excitation supply short circuit
2 +Wire-break detect
74 The Solutions Module has overheated.
SM-Applications
Freeze
flag
x.13
x.10
x.15
Equivalent
lines per
revolution
Resolver
excitation
Resolver
poles
Error detection
level
Term Resolver connections
9 SIN LOW
10 SIN HIGH
11 COS LOW
12 COS HIGH
13 REF HIGH (excitation)
14 REF LOW (excitation)
15 0V
16 0V
17 0V
x.39
x.17
Freeze input
SM-Universal
Encoder Plus
x.35
Freeze
revolution
counter
Freeze positional
information
x.36
Freeze
position
9-Way

Table of Contents