Protection functions
108
© 2022 KEB Automation KG
4.4.24.3.2 Display in the ru parameters
If a value not equal to zero is parameterized in pn87[1] blockage mode->warning,
bit blockage warning is displayed in ru02 and ru03.
ru03
warning state
0x2C03
Value
Plaintext
Note
137
blockage warning ac-
tive
Blockade warning bit is set and no higher priority message is
active
ru02
warning bits
0x2C02
Bit
Plaintext
Note
18
blockage warning
Blockade warning bit is set
Whether 7: warning is also set in the statusword st00 or 0x6041 when the block-
ade warning bit is set can be defined via the object pn28 warning mask.
Monitoring of the load
Parameter ru80 relative load is used to display the load of the entire drive system
consisting of inverter, motor and application against torque and thermal limits.
No automatic reaction can be made dependent on the load display.
In the previous software versions, the rated torque was predefined by the drive.
Object pn88 now allows you to choose between different options for defining the
rated torque.
Configuration of the load display:
pn88
display configuration
0x2515
Bit
Function
Valu
e
Plaintext
Note
0,1
display
mode
0
standard display
Standard display in ru80:
ru50 / ru51 > 100% => ru80 = ru24 actual torque
ru50 / ru51 100% => ru80 = ru24 / ru50 (or ru51)
1
extended display
Display is configured by the settings in bit 2..7
2,3
drive
reference
0
no drive limit
Inverter limits are not consisered
4
actual torque limit
Reference: 100% = current torque limit ru50 / ru51
(= limiting characteristic + parameterized torque limits
in the cs parameters + effective current limits)
4,5
application
reference
0
no application
limit
Parameter pn88[2] application torque limit has no in-
fluence on the display in ru80
16
constant limit
100% = pn88[2] constant torque limit
=> Application torque limit
6,7
thermal
limit
0
no thermal limit
the thermal load is not considered
32
thermal limit
Up to the rated speed, the reference for the actual
torque is dr09 rated torque, then the thermal perma-
nently available torque is reduced according to a 1/x
function, independent of the motor type . (Thermal
load)

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals