Minimum switch-off time of the modulation not yet expired
Power Off function active
A protection time (minimum switch-off time after error) is active
For more detailed information see chapter (4.4.23 Minimum switch-
off times.
An applied error leads to modulation shutdown, but it is not dis-
played as an error in ru01 and the state parameters.
The detailed description of the single states of the state machine and the changes
can be found in chapter 4.1 State machine.
Value of ru01 (see 4.3.1 Errors)
This parameter is used to indicate the reason for the triggering of a stop function
(Fault-Reaction / ShutDown / Quickstop / DisableOperation), even if the internal
error state is no longer present during the ramp.
The display of the error is not reset via a reset, but only by the request of a new
state machine change via the internal controlword.
Affect the behaviour of the state machine
The behaviour of the state machine can be affected via parameter co32 state ma-
chine properties.