Determination of the actual state of the state machine from the status word:
State of the state machine
Display of the actual state
The current state of the state machine can be read out directly.
actual state of the state machine (KEB spec. object)ob-
ject)
Error and state machine display
The meaning of the values of st12:
This state is pass through after switching on the control voltage (ini-
tialisation of the control hardware and software).
The modulation cannot be enabled yet.
In addition to the controlword bits, causes can be missing STO sig-
nals or missing mains voltage.
The bit "enable voltage" is not yet set, the preconditions STO sig-
nals and mains voltage are given
The "enable operation" bit is missing to enable modulation
Modulation is enabled, the state machine has started, no exception
(e.g. stop mode) is active for the handling of the state machine.
The quick stop reaction is carried out
The error / fault reaction is carried out. Modulation is still active.
Fault (modulation switched off)
"Shutdown“ or "Disable operation“ is executed according to the
mode selected in co32
Start function active (e.g. flux build-up, brake opening)