Operating modes
© 2022 KEB Automation KG
149
1
2
3
Setpoint (vl20 vl target velocity)
Acceleration (defined by co48co59)
Ramp output value (ru06 ramp out display)
21
1fghfh
1
Figure 40: pass zero type = 0: not zero
The acceleration remains on the actual value, if the ramp output changes the sign.
If the acceleration, as in this example, has a different value in the other direction,
the acceleration changes with the actual jerk to the new value.
1
2
3
Setpoint (vl20 vl target velocity)
Acceleration (defined by co48co59)
Ramp output value (ru06 ramp out display)
21
1fghfh
1
Figure 41: pass zero type = 8: zero
The acceleration is reduced to 0 when the ramp output changes the sign.