Digital outputs
© 2022 KEB Automation KG
463
Generation of the internal outputs
7.2.12.1 Parameter overview
The internal outputs (= outputs of the comparator level) can be used as source for gener-
ation of the output state.
It can be determined with do19 AND operation for output whether the flags should be
linked OR (standard) or AND (adjustable with do19).
Which flags are used to generate an internal output is parameterized via the objects
do20...do27.
Index
Id-Text
Name
Function
0x2613
do19
AND operation for output
Selection of the link type for output O1…OD
0x2614
do20
select flag O1
Selection of the flags for internal output O1
0x2615
do21
select flag O2
Selection of the flags for internal output O2
0x2616
do22
select flag O3
Selection of the flags for internal output O3
0x2617
do23
select flag O4
Selection of the flags for internal output O4
0x2618
do24
select flag OA
Selection of the flags for internal output OA
0x2619
do25
select flag OB
Selection of the flags for internal output OB
0x261A
do26
select flag OC
Selection of the flags for internal output OC
0x261B
do27
select flag Relais
Selection of the flags for the relay
0x261C
do28
invert flags for output
Selection of which flags are to be inverted before
linking
The selection which flags are to be inverted for the generation of the respective output
signal is made in the array do28.
The selection for output O1 is made in do28[1], for output O2 in do28[2], for output O3 in
do28[3], etc. up to do28[8] for the relay output. Not all outputs are available on all control
card types. (see also the overview in Figure 125: Comparator levelFigure 124: Digital out-
puts block diagram)
do28
invert flags for output
0x261C
Bit
Valu
e
Name
Function
0
1
F1
Invert flag 1
If several function blocks are se-
lected for one output, the selected
flags are OR-connected (output is
set if at least one flag is set) or
AND-connected (output is set if all
assigned flags are set).
The type of connection is defined in
do19.
1
2
F2
Invert flag 2
..
..
..
...
7
128
F8
Invert flag 8
8
256
CF1
invert linked function blocks 1
..
..
..
11
2048
CF4
invert linked function blocks 4

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals