Operating modes
154
© 2022 KEB Automation KG
4.8.3.5 Homing methods
Index
Id-Text
Name
Function
0x3101
hm01
(CiA 0x6098) homing method
Selection of the zero point search
With slave-based homing, the limit switches are always active. A setpoint is only
enabled if the corresponding limit switch is also set.
The logic of the digital inputs can be adjusted with di00 thereby a test operation of
the homing functions is also possible.
4.8.3.5.1 Method 1 (17) Homing to the negative limit switch and zero track
21
1fghfh
1
Figure 43: Homing Method 1
Method 1 is started first with negative direction of rotation with the adjusted set-
point in hm02 (as shown in the figure above).
When approaching the negative limit switch, the drive reverses and removes the
limit switch with the setpoint set under hm03.
Then the drive moves to the next zero signal of the encoder.
At this point the drive stops and the homing offset is transferred to the actual posi-
tion.
Method 17 corresponds to method 1, but without zero signal search.

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals