Motor parameterization
372
© 2022 KEB Automation KG
Switching frequency adjustment and derating
Index
Id-Text
Name
Function
0x2021
de33
inverter rated switching frequency
Rated switching frequency
0x2022
de34
inverter max switching frequency
Maximum switching frequency
0x350A
is10
switching frequency
Selected switching frequency
0x350F
is15
temp dep derating
Activation of the temperature-dependent switch-
ing frequency reduction
0x3510
is16
min. derating frequency
Lower limit for the current / temperature-depend-
ent switching frequency reduction
0x3516
is22
basic Tp
Selection of the switching frequency group
0x2C48
ru72
act.switch.freq (kHz)
Actual switching frequency
6.2.20.1 Set switching frequency
is10
switching frequency
0x350A
Value
Meaning
2…16.0 kHz
Set switching frequency in 0.1 kHz resolution
is22
basic Tp
0x3516
Bit
Func-
tion
Value
Plaintext
Notes
0…2
basic
Tp
0
62.5 µs / 16 kHz, 8 kHz, 4 kHz, 2 kHz
Selection of the switching fre-
quency group
1
71.4 µs / 14 kHz, 7 kHz, 3.5 kHz, 1.75 kHz
2
83.3 µs / 12 kHz, 6 kHz, 3 kHz, 1.5 kHz
3
100 µs / 10 kHz, 5 kHz, 2.5 kHz, 1.25 kHz
The switching frequency can be selected in parameter is10. Only data that are per-
mitted as associated values for the selected switching frequency group are ac-
cepted.
If the switching frequency group 0: 62.5 µs / 16 kHz, 8 kHz, 4 kHz, 2 kHz is param-
eterised in is22, only 2, 4, 8 or 16 kHz can be set for is10.
Due to the used power unit, further restrictions on the possible switching frequen-
cies can become effective.
The indicated values in the manual for the maximum current are valid for the rated
switching frequency (de33).
Parameter de34 indicates the maximum switching frequency which is permissible
for this inverter.
The lower limit of the switching frequency is determined by the used inverter and
the minimum application-specific switching frequency (sinus filter dr53).
These limits have priority to the settings of is10 switching frequency or is16 min.
derating frequency.
The output frequency-dependent short-time current limits reduce at increased
switching frequency (=> Chapter 4.4.2 Overload power components (OL2)).

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals