Protection functions
72
© 2022 KEB Automation KG
Fieldbus watchdog
Independent on the control the drive can be stopped with the function fieldbus
watchdog when the communication is interrupted.
The function can be parameterized via the following objects:
Index
Id-Text
Name
Function
0x2A15
pn21
fieldbus watchdog time
Max. period of the communication interruption (0 = off)
0x2A16
pn22
E.fb watchdog stop mode
Error reaction (=> see Chapter 4.3.1 Errors)
0x2C02
ru02
warning bits
Display of the warnings bit-coded (=> 4.3.3 Warnings)
0x2A1C
pn28
warning mask
Mask for warning bit in the status word (=> 4.3.3 Warn-
ings)
A detailed description of the functionality of the fieldbus watchdog can be found
from version 3.0 in the Programming Manual | Fieldbus systems.
The Programming manual | Fieldbus systems can be downloaded from the KEB
website. Registration is required.