6.2.13.2 Effect of the saturation characteristic
Which control parameters are influenced by the saturation can be selected with
mo00:
dr14,
dr09/dr03,
dr11/dr12
Change of the EMF according to the 3 points
characteristic (no-load operation, nominal set-
point, maximum point)
saturation coef-
ficients (mo01)
The saturation coefficients of the motor are de-
termined via an external tool and entered in
mo01.
Change of the EMF proportional to the active
current
The consideration of the saturation characteristic for the EMF and thus for torque
=> current or current => torque conversion is activated with bit 0,1 = 1.
Bit 2 defines the factors determining the saturation characteristic. Currently, the
saturation factor is always considered as active current-dependent.
Ld changes according to the EMF
Do not adjust for future extensions!
Lq changes according to the EMF
Do not adjust for future extensions!
The consideration of the saturation characteristic for inductances is activated wit bit
3,4 = 0 or bit 7,8 = 0.
Currently the inductances can only be changed according to the saturation charac-
teristic (EMF proportional).
Then the adapted inductance values are considered by the decoupling, the motor
model and used by the torque calculation.