Torque limits
414
© 2022 KEB Automation KG
Example:
The control presets only the motor torque limit, regenerative parameterization shall
be effective for positive and negative speed in cs15 torque limit gen. for.
cs12 = 150%, absolute limitation
cs13 (mot. forward) is preset via the bus address 270Eh
(value 1000 => 100% => Mn)
cs14 (mot. reverse) = -1: mot.forward = cs13
cs15 (gen. forward) = 90%
cs16 (gen. reverse) = -1: gen. forward = cs15