Digital Inputs
436
© 2022 KEB Automation KG
co29
source connection definition
0x251D
Bit
Function
Value / plaintext
Description
0..4
function type 0
definition
0
only co00 bits
only controlword
1
only digital inputs
only digital input controlword
2
co00 AND digital inputs
Controlword AND digital input CW
3
co00 OR digital inputs
Controlword OR digital input CW
5..9
function type 1
definition
0
only co00 bits
only controlword
32
only digital inputs
only digital input controlword
64
co00 AND digital inputs
Controlword AND digital input CW
96
co00 OR digital inputs
Controlword OR digital input CW
20..22
function nr se-
lector
0
connection type 0 active
connection type 0 always active.
1048576
choose type with bit 11
Choose connection type with bit 11
of the „preliminary controlword“
2097152
choose type with bit 12
Choose connection type with bit 12
of the „preliminary controlword“
3145728
choose type with bit 13
Choose connection type with bit 13
of the "preliminary controlword“
Depending on the parameterization of co29 source connection definition => func-
tion nr selector, bits 11..13 of the "preliminary controlword" can be used to switch
between the different connection types at runtime.
Alternatively, only one connection type can be used.
In this case, "the manufacturer specific" bits of the controlword remain usable for
other extensions.
NOTICE
The bits defined by the combined controlword mask are serially evalu-
ated. This means: a connection defined in combined controlword mask
[1] is overwritten by another connection defined in combined controlword
mask [2] or [3 ].

Table of Contents

Other manuals for KEB COMBIVERT F6

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
CategoryController
SeriesCOMBIVERT F6
TypeFrequency inverter
Output Voltage0 to Input Voltage
Output Frequency0 to 400 Hz
Frequency Range0 to 400 Hz
Control MethodV/f control
Communication InterfacesCANopen, PROFIBUS
Protection ClassIP20
CoolingNatural cooling
SafetySafe Torque Off (STO) according to EN 61800-5-2
ApplicationGeneral industry, pumps, fans, conveyor systems
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheating
Ambient Temperature-10°C to +40°C
Enclosure RatingIP20